** For advices on installation please refer to our videos on our website.
Before installing recessed fixtures it is important to identify in what type of ceiling they will be installed.
The type of ceiling determinates the level of complexity for installation and which accessories will be required.
Note: BAZZ recessed fixtures can only be installed with BAZZ accessories.
Caution! We recommend using the services of a qualified electrician for installation. Wiring has to be done and secured by an electrician. Please refer to the Electrical code of your region.
01The fixture is inserted in the ceiling hole opening and fastened with 2 screws. For the righ hole diameter, refer to the template included with packaging.
The plaster frame is inserted in between the ceiling and the fixture to fastened the installation without damaging the ceiling.
For PF2002/PF606 installation, cut the frame where indicated and insert it through the ceiling hole opening.
For PF1101 installation, lateral bar hangers are fastened to the structure.
The plaster frame is inserted in between the ceiling and the fixture to fastened the installation without damaging the ceiling.
For installation, lateral bar hangers are fastened to the structure.
The plaster frame is inserted in between the ceiling and the fixture to fastened the installation without damaging the ceiling.
For installation, cut the frame where indicated and insert it through the ceiling hole opening..
With exterior soffit ceiling, only series 200 and 400 can be installed.
The insulated ceiling box separates insulation material from the fixture, indicates where to install the fixtures and where the ceiling openings have to be done once the gypsum is installed.
The vapor barrier is recommended to avoid risks of condensation and waste of energy.
For installation, you need to have access to the ceiling space to install 1) the insulated ceiling box by fastening the bar hangers to the structure 2) the vapor-barrier above the insulated ceiling box.
We recommend using the PF1101 plaster frame to indicate where to install the fixtures and where the ceiling openings have to be done once the gypsum is installed.
For installation, lateral bar hangers are fastened to the structure.
The insulated ceiling box separates insulation material from the fixture, indicates where to install the fixtures and where the ceiling openings have to be done once the gypsum is installed.
The vapor barrier is recommended to avoid risks of condensation and waste of energy.
For installation, you need to have access to the ceiling space to install 1) the insulated ceiling box by fastening the bar hangers to the structure 2) the vapor-barrier above the insulated ceiling box.
CAUTION! In an insulated ceiling a minimum height of 7 ½ inches is required to install the mandatory insulated ceiling box (BT1200). This excludes additional space required for insulation material. Please refer to the Electrical code of your region.
If the height is under 7 ½ inches, LED or CFL recessed fixtures approved for insulated ceiling as is, with no insulated ceiling box required can be installed. Please refer to product specifications.
SERIES | 4 ½ ≤ H ≤ 5 | 5 ≤ H ≤ 6 | 6 ≤ H ≤ 7 | 7 ≤ H ≤ 8 | 8 ≤ H ≤ 9 |
---|---|---|---|---|---|
100 | |||||
200 | |||||
300 / 300 pro | |||||
303 | |||||
303LED | |||||
400 | |||||
500 | |||||
606 | |||||
800 / 803 | |||||
900 | |||||
JIB 3 3/8 | |||||
JIB 3 7/8 | |||||
CFL100 | |||||
CFL400 | |||||
CUBE |
SERIES | 0 ≤ T ≤ ¼ | ¼ ≤ T ≤ ½ | ½ ≤ T ≤ ¾ | ¾ ≤ T ≤ 1 | T > 1 |
---|---|---|---|---|---|
100 | |||||
200 | |||||
300 / 300 pro | |||||
303 | |||||
303LED | |||||
400 | |||||
500 | |||||
606 | |||||
700 / 703 | |||||
800 / 803 | |||||
900 | |||||
JIB 3 3/8 | |||||
JIB 3 7/8 | |||||
CFL100 | |||||
CFL400 | |||||
CUBE |